High-volume production: void-affected area below 1%, up to 650 °C, automated door on the 300A

The c.VACUNITE 300 and 180 multi plate systems are designed for vacuum-based thermal processing in high-volume production. They meet the highest requirements of ultra-clean, voidless soldering for advanced packaging and power semiconductors. The c.VACUNITE 300A with automated door closure suits fully automated production lines.
Processes run under pure, oxygen-free atmospheres, with surface activation by 100% hydrogen, formic acid or forming gas. The void-affected area can be reduced to less than 1%, while common reflow soldering systems range at 5%.


| Model | c.VACUNITE 300A | c.VACUNITE 300 | c.VACUNITE 180 |
|---|---|---|---|
| Plate size | 540 × 410 mm | ||
| Max. substrate height | 100 mm | ||
| Max. load per plate | 25 kg | ||
| Heating plates | 5 | 5 | 3 |
| Process gases | N2, H2 (100%), N2H2 (95/5), HCOOH | ||
| Vacuum level | 0.1 mbar | 0.1 mbar (opt. 10-5 mbar) | 0.1 mbar (opt. 10-5 mbar) |
| Vacuum pump (oil sealed) | 40 / 65 m³/h | ||
| Heat-up rate* | 40 K/min | ||
| Cool-down rate* | 150 K/min | ||
| Process temperature | up to 450 °C | up to 450 °C (opt. 650 °C) | up to 450 °C |
| System weight | 1600 kg | 1500 kg | 1200 kg |
| Dimensions (L × W × H) | 1427 × 1428 × 2395 mm | ||
* Values may vary depending on the specific system design.
→ Request a quotation or a consultation
InterElectronic is your contact for Centrotherm vacuum soldering systems and furnaces.